Product Accessories Introduction
① Window opener motor
② 2 PCS Hex Screw
③ 2 PCS Motor installation bracket
④ 1 of R-lockpin
⑤ 1 of Chain connector bracket
⑥ 1 of T-lockpin
⑦ 8 PCS Screw (ST5*16)
⑧ Remote signal antenna
⑨ Rain Water sensors
Installation matters need attention
1. The window opener can run a round trip before installation, to check whether the window opener is in good
condition before installation.
2. Check whether the window opening travel limit is longer than the window opener opening travel limit, and
whether the window opening is worked as well.
3. When installing the Chain connector bracket, the T-lockpin direction should be consistent with the chain
connection port;
4. Chain and window Casing can not contact, need to maintain more than 3 mm distance;
5. The window opener should turn off the electricity of the controller before working to prevent the danger
of electric shock.
6. When the window opener is running, do not put your hand between the window frame and the window sash
to prevent the danger of hand clamping
7. The window opener installation must be performed by a professionally trained personnel to install and connect
the wiring. the installer must be familiar with the technical parameter standards and safety standards of the
intelligent window control system.
Use and maintenance considerations
1. When this product is installed, the installation personnel must operate according to the national safety rules
to ensure the operation safety.
2. This product can not be directly installed in the rain to the outdoor.
3. This product is not configured to prevent clamping hand function, when installation or use should pay
attention to safety;
4. When it‘s a AC motor, plug directly into VAC 220 power socket.
5. Customers who purchase our products should contact us and register in time to obtain warranty service and
after-sale maintenance service.
6. Ensure windows are safe during installation and removal of window opener to avoid accidents.
7. If the window opener is installed at a height of more than 25 meters, provide the installation personnel with
a platform or support.
8.If the window opener function failure and damage, please contact the selleror after-sales service engineer,
do not use the window opener before repair;
Every year must regularly check whether the wire is damaged, installation bracket and other fasteners fixed condition.